- Pagina iniziale /
- forniture industriali /
- Test, Measure & Inspect /
- Substance Analysis Instrumentation /
- Electrodes /
- Total Ionic Strength Adjustment Buffer (TISAB...
Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes
€ 170
Price Details
Excluding Shipping & Custom charges ( Shipping and custom charges will be calculated on checkout )
*All items will import from Stati Uniti
QTY:
Ubuy works hard to protect your security and privacy. Our advanced payment security system ensures confidentiality by encrypting your information during transmission using AES (Advanced Encryption Standards) and SSL (Secure Socket Layer) protocols. Your payment details are 100% secure as we do not share your payment details with third party sellers.
Ready-to-use solutions provide savings in raw materials, labor and waste disposal.
Buy Now Pay Later
Consegna
veloce
Reso
gratuito*
Imballaggio sicuro
Prodotti originali al 100%
Conformità PCI DSS
Certificazione ISO 27001
Cosa salta all'occhio
Dettagli del prodotto
| Peso del artículo | 1.5 lbs (680 gram) |
A chi è consigliato?
-
Laboratory Technicians
Essential for technicians conducting fluoride analysis using ion selective electrodes in various laboratory environments.
-
Environmental Scientists
Ideal for scientists assessing water quality and fluoride concentrations in environmental samples and field studies.
-
Investigadores Académicos
Beneficial for researchers in academia performing experiments related to fluoride chemistry and ion analysis.
-
Usuarios domésticos
Not suitable for casual users without specialized knowledge or equipment for fluoride testing at home.
-
Non-technical Professionals
May be overwhelming for professionals lacking technical expertise in ion selective electrode usage and chemical analysis.
-
Small Scale Applications
Not recommended for small, infrequent tasks where comprehensive fluoride analysis techniques are unnecessary.
DESCRIZIONE DEL PRODOTTO
Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes
Domande e risposte dei clienti
-
domanda:
What is TISAB II and its role in fluoride analysis?
Rispondere: Total Ionic Strength Adjustment Buffer (TISAB II) is a specialized buffer solution used to stabilize ionic strength during fluoride analysis with ion-selective electrodes. It ensures accurate readings by maintaining consistent ionic conditions, which is crucial for the reliability of fluoride measurements in various samples, such as drinking water or biological fluids. The presence of CDTA in TISAB II enhances its effectiveness by binding with interfering metal ions, providing clearer and more precise analysis outcomes. -
domanda:
How do I use TISAB II with ion-selective electrodes?
Rispondere: To utilize TISAB II effectively, first prepare your sample by diluting it as necessary, then add TISAB II in a defined ratio. This mixture can be directly introduced to an ion-selective electrode designed for fluoride detection. The buffer's function is to control ionic strength and minimize interferences, which is vital for obtaining precise and reproducible fluoride concentration readings in environmental samples or clinical assessments. -
domanda:
What are the main components of TISAB II?
Rispondere: TISAB II primarily consists of a blend of buffers that stabilize pH and ionic strength, along with CDTA, which is a chelating agent that binds metallic ions. This combination enhances the accuracy of fluoride detection by minimizing the effect of contaminants and competing ions in the sample. By ensuring that the analytical conditions are consistent, TISAB II plays a key role in various applications, from water quality testing to food safety analysis. -
domanda:
Why is CDTA included in TISAB II?
Rispondere: CDTA, or trans-1,2-diaminocyclohexane-N,N,N',N'-tetraacetic acid, is included in TISAB II to enhance the buffer’s ability to remove potential interference from metal ions. These ions can adversely affect the performance of the ion-selective electrode used for fluoride analysis. By binding with these interfering species, CDTA helps in obtaining more reliable and accurate fluoride concentration measurements, which is particularly important in regulatory compliance and research scenarios. -
domanda:
Can TISAB II be used for other ions aside from fluoride?
Rispondere: While TISAB II is primarily designed for fluoride analysis, its buffered system can be adapted for other ions that require significant ionic strength adjustments. However, its specificity and the effectiveness of CDTA may not be the same for every ion type. Researchers often use TISAB II in conjunction with the appropriate ion-selective electrodes tailored for the specific analyte being tested, ensuring reliable readings in various analytical contexts. -
domanda:
What is the recommended storage condition for TISAB II?
Rispondere: TISAB II should be stored in a cool, dark place, ideally at room temperature, to maintain its integrity. It is important to keep the buffer away from direct sunlight and extreme temperatures, which can degrade the solution over time. Proper storage ensures that the buffer maintains its optimal pH and ionic strength, crucial for accurate fluoride analysis when utilized in testing laboratories or field applications. -
domanda:
How does TISAB II affect the pH of a sample?
Rispondere: TISAB II is formulated to maintain a neutral pH, typically around 5.0 to 5.5, which is ideal for fluoride measurements. Adding TISAB II to a sample helps to regulate its pH, crucial for ensuring that fluoride exists in a stable, measurable state. This controlled pH environment is essential in achieving accurate calibrations and results, especially in water quality assessments or food analysis, where pH can fluctuate significantly. -
domanda:
Is TISAB II compatible with all ion-selective electrodes?
Rispondere: TISAB II is primarily used with ion-selective electrodes designed specifically for fluoride detection. However, compatibility can vary based on the electrode’s chemistry and design. It is advisable to consult the manufacturer’s guidelines for specific electrodes to ensure they are suitable for use with TISAB II. This compatibility check is particularly essential to avoid erroneous readings in scenarios like environmental monitoring or product testing. -
domanda:
What types of samples can be analyzed using TISAB II?
Rispondere: TISAB II can be used to analyze a broad range of samples, including drinking water, wastewater, food products, and biological samples such as saliva or serum. Each sample type may require specific preparation steps, such as dilution prior to adding TISAB II, to ensure that fluoride concentration can be accurately quantified. This versatility makes TISAB II invaluable in laboratories working on environmental, health, or safety assessments. -
domanda:
Where can I buy Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes in Italy?
Rispondere: You can purchase Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes at Ubuy. Ubuy offers a wide selection of chemical products and laboratory supplies, making it a reliable source for your analytical needs in Italy. The platform provides easy access to institution-quality reagents perfect for both professional and academic use.
RiccaChemical Electrodes Editorial Review
Recensioni e valutazioni del cliente
-
5 stella
100%
-
4 stella
0%
-
3 stella
0%
-
2 stella
0%
-
1 stella
0%
Recensisci questo prodotto
Condividi le tue impressioni con altri clienti
Cronologia dei prezzi del prodotto
Informazioni importanti
- Limitazioni: per i prodotti spediti a livello internazionale, si prega di notare che ogni garanzia del produttore potrebbe non essere valida, le opzioni di assistenza del produttore potrebbero non essere disponibili, i manuali del prodotto, le istruzioni e gli avvisi di sicurezza potrebbero non essere nella lingua del paese di destinazione. I prodotti (e i materiali di accompagnamento) potrebbero non essere progettati in conformità con gli standard, le specifiche e i requisiti di etichettatura del paese di destinazione e i prodotti potrebbero non essere conformi alla tensione di rete del paese di destinazione e ad altri standard elettrici (richiedendo l'uso di un adattatore o di un trasformatore, se necessario). Il destinatario è responsabile di assicurare che il prodotto possa essere legalmente importato nel paese di destinazione. Quando si ordina da Ubuy o dai suoi affiliati, il destinatario è l'importatore registrato ed è tenuto a rispettare tutte le leggi e i regolamenti del paese di destinazione.
- Non tutti i prodotti elencati su Ubuy sono in vendita, poiché Ubuy è un motore di ricerca globale. I prodotti sono soggetti a regolamenti di esportazione/commercio.
€ 170
Ordina subito e indossalo Venerdì, Luglio 10
Questo articolo non è vietato nel mio paese. (Fai clic sul link se questo articolo non è vietato nel tuo paese. In questo modo, il nostro team verificherà il permesso).
QTY:
Ubuy works hard to protect your security and privacy. Our advanced payment security system ensures confidentiality by encrypting your information during transmission using AES (Advanced Encryption Standards) and SSL (Secure Socket Layer) protocols. Your payment details are 100% secure as we do not share your payment details with third party sellers.
Caratteristiche e benefici
- Manufactured with ACS Reagent grade raw materials.
- Intended for precise Fluoride Analysis using Ion Selective Electrodes.
- Lot numbered and expiration dated for quality assurance.
- Tight specifications ensure the most accurate results.
- Minimal lot-to-lot variation enhances reproducibility.
- Certified traceable to NIST for regulatory compliance.